LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
CS1W-HCA12-V1 OMRON CS1W-HCA12-V1
Brand: OMRON
Name:
Model: CS1W-HCA12-V1
Type: Analog inputs, counter inputs, analog outputs.
12 DC inputs: Yes.
Counter inputs: 1.
Analog inputs: 1.
8 transistor outputs: Yes.
2 pulse outputs: No.
2 analog outputs: Yes.

Unit type: CS1 Special I/O Units.
Name: High speed Counter Units.
Specifications: Countable channels,
2; Encoder A and B inputs,
pulse input Z signals, Open collector,
Input voltage: 5VDC,12VDC, or 24VDC,
(only 1 axis for 5 V or 12 V input),
RS-422 line driver;
Max. counting rate, 50kHz, 500kHz OMRON CS1W-HCA12-V1.
No. of unit numbers allocated: 4.
Current consumption: 5V, 0.36A; 26V, -- CS1W-HCA12-V1
Standards: UC, N, L, CE.
High-Speed, Flexible Control With A,
Wide Array of Features.
Equipped with 2 or 4 Counters and counts,
over a maximum binary range of 32-bits.
Accepting input pulse frequencies of up,
to 500 kHz allows precise control of fast motions.
The Unit is equipped with 4 Digital Inputs,
4 Digital Outputs and 28 Soft Outputs OMRON CS1W-HCA12-V1.
A maximum response time of 0.5 ms guarantees,
high-speed closed loop control of applications. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
250 ms/8 inputs.
Externa connection: Removable erminal block OMRON CS1W-HCA12-V1.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices CS1W-HCA12-V1 OMRON.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value CS1W-HCA12-V1 OMRON.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them CS1W-HCA12-V1 OMRON.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacce compared,
with previous systems CS1W-HCA12-V1.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems OMRON CS1W-HCA12-V1.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.