The PLC point on the MITSUBISHI system is effectively enforced
Time: 6/7/2017 11:20:39 PM

For examp6 PLC this PLC point, in general, I monitor the screen, enter the X6-1-2 will be effective, can not permanently effective? What needs to be done because the machine is so old that there's nothing else to do
And what are the MITSUBISHI spindles, the high and low X signals and the Y signals?
Re:   Time: 6/8/2017 3:26:00 AM
The method you use in monitoring screen is forced off after not effective, if you want to keep, permanent, can put a normally open contact X6 into a normally closed contact in PLC, or find the input signal X6, continue to provide 24V voltage.
The X gear shift signals for M6 are X1E and X1F, and the Y signals are Y6 and Y7