LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
E6C3-CWZ3EH 1500P/R 2M
No PHOTO
OMRON E6C3-CWZ3EH 1500P/R 2M
Actuator: Roller plunger.
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available . )
M12-connector models are also available, saving on labor and,
simplifying replacement E6C3-CWZ3EH 1500P/R 2M
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC E6C3-CWZ3EH 1500P/R 2M. Improved update. Reduce standby power consumption, and then achieve lightweight .
Standby power consumption reduced to 85% of the company''s previous products. (61F-GN)
The quality is reduced to less than 85% of the company''s previous products. (61F-G3N, G4N)
With LED action display function, so that the state of action at a glance.
By improving the reliability of internal relays (tiny load 1mA DC5V), the PLC input becomes possible E6C3-CWZ3EH 1500P/R 2M.
The electrode side terminals and other wiring terminals are separated, so the wiring operation is simple .
Installation method can choose the JEM agreement, DIN guide rail installation, screw installation in 3 ways.
Type: G3N type, both full of water, water shortage alarm function of automatic supply and drainage.
Package product name: 61F-G3N base * 1, 61F-11_ unit * 3.
Purpose: long distance use (4km). Input capacity: 16 points.
Internal I/O common: NPN.
ON voltage: 15 VDC min. (between each in,
put terminal and the V terminal).
OFF voltage: 5 VDC max. (between each in,
put terminal and the V terminal).
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms,
1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms.
(Default setting: 1ms)
Number of circuits per common: 16 points/common.
Input indicators: LED display (yellow).
Isolation method: No isolation.
I/O power supply method: Supplied from unit power supply.
Input device supply current: 50 mA/point.
Unit power supply current consumption: 150 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 140 g max.
Expansion functions: No.
Short-circuit protection function: Available.
(Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CONN connectors E6C3-CWZ3EH 1500P/R 2M.
A common terminal is provided for,
each connector .
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
sswiitch and with tool software E6C3-CWZ3EH 1500P/R 2M.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.
E6C3-CWZ3EH 1500P/R 2M Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=E6C3-CWZ3EH 1500P/R 2M&select=5