Power supply: AC power supply.
Output method: Transistor output sink type.
Inputs points: 12 points.
Outputs points: 8 points.Size: 45 × 35 mm.
Type: Plug-in.
Control method: ON/OFF operation.
Control output: Relay.
Power supply voltage: 100 to 240 VAC.
Ideal for Simple Built-in Control.
A high switching capacity of 10 A at 250 VAC enables,
direct load switching E6B2-CWZ6C 50P/R 0.5M.
A sensor is provided to enable immediate application
E6B2-CWZ6C 50P/R 0.5M
Sockets with finger protection (PTF14A-E) or without,
finger protection (PTF14A) can be used.
Simple operation and settings. Even simpler with digital models. Input capacity: 16 points.
Rated current (ON current): 0 E6B2-CWZ6C 50P/R 0.5M. 5 A/output, 4.0 A/common.
Internal I/O common: PNP .
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the V terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply E6B2-CWZ6C 50P/R 0.5M.
Output device supply current: 100 mA/point .
Unit power supply current consumption: 80 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 130 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.
Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Screw mounting.
Applicable load: 15 A, 200 to 480 VAC.
Number of pole: 2.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN TTrack Mounting E6B2-CWZ6C 50P/R 0.5M. .
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIIN Track mounting types mount to DIN Track E6B2-CWZ6C 50P/R 0.5M.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification).
E6B2-CWZ6C 50P/R 0.5M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E6B2-CWZ6C 50P/R 0.5M&select=5