Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A).
Operation: Momentary operation (Self-resetting).
Case color: Light gray.
Output: DPDT.
Lighting: LED; 24 VDC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness E5EN-Q3HHT-N AC100-240.
Three-color models (green, orange, red; chameleon lighting)
E5EN-Q3HHT-N AC100-240
included in lineup. Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points E5EN-Q3HHT-N AC100-240.
Heater break, SSR fault detection function: - .
Event input points: -.
Transfer output: -.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm) E5EN-Q3HHT-N AC100-240.
High speed sampling period 60ms .
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. DIN Track Mounted, Standard 17.5-mm Width Timer Range.
A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number, of timer models kept in stock. (24 to 230 VAC/VDC with H3DS-XL@).
Smart Dial/Selector-locking Mechanism: Prevents the dials and selectors on the, Timer’s front panel from being inadvertently op.
erated or being operated without authorization. The lock can only be unlocked and, locked with an optional pen-type Lock Key.
Screw-Less Clamp type available. (H3DS-@LC).
Sticker provideed for easy tiimer identification and management E5EN-Q3HHT-N AC100-240.
Terminal clamp left open when delivered (screw terminal type).
Finger protection terminal block to meet VDE0106/P100.
Enables easy sequence checks through instantaneous outputs for a zero,
set value at any tiimee range E5EN-Q3HHT-N AC100-240.
Incorporates environment-friendly, cadmium-free contacts.
Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Voltage, and EMC Directives.
E5EN-Q3HHT-N AC100-240 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E5EN-Q3HHT-N AC100-240&select=5