Name: Temperature Sensor Module.
Model: C200H-TS101.
Temperature sensor: RTD (JPt 100 Ω.).
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected).Head material: Plastic.
Release key position: Bottom.
Release key type: Standard (resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC .
Lock and release types: Solenoid lock Mechanical release E5CN-HQ2H03D-FLK AC/DC24.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 2NC/1NO+2NC
E5CN-HQ2H03D-FLK AC/DC24
Conduit opening: M20.
Best-selling Guard Lock Safety-door.
Switch Available in Several E5CN-HQ2H03D-FLK AC/DC24.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility .
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available E5CN-HQ2H03D-FLK AC/DC24. Output: SPDT.
Lighting: LED.
Operating voltage: 12 VAC/VDC .
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Compact Size, High Performance.
Superb functionality with a compact screen size. Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Pin plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulatiing material E5CN-HQ2H03D-FLK AC/DC24.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfiirmation of operation E5CN-HQ2H03D-FLK AC/DC24.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
E5CN-HQ2H03D-FLK AC/DC24 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E5CN-HQ2H03D-FLK AC/DC24&select=5