Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 1NC/1NO(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms .
(Slow-action models with MBB contacts are available E5AK-TPRR2-K-500 AC/DC24. )
M12-connector models are also available, saving on labor and,
simplifying replacement
E5AK-TPRR2-K-500 AC/DC24
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) E5AK-TPRR2-K-500 AC/DC24.
Certified standards: UL, EN (TÜV), and CCC . Easy Mounting and Removal. Ideal for,
Applications in Deep Wells.
Applicable in locations where space is limited between the water,
tank and ceiling.
The PH-1 is used for applications where wastewater and scum,
accumulates, such as for a deep well pump. The PH-2 is used for,
applications where the distance to the water surface is long E5AK-TPRR2-K-500 AC/DC24. Case color: Light gray.
Lighting method: LED; 24 VDC .
Display color symbol: R.O.G.W.
Large Rectangular-bodied Indicators.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting),
included in lineup. Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A).
Operation: Alternate operation (Self-holding).
Case color: Black.
Output: DPDT.
Lighting: LED; 24 VDC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting).
included in lineup. Model: C500-CN131.
Cable length: 10 m.
Programming Console Connecting Cable.
For extension and connection of FIT of FIT.
Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (VVer E5AK-TPRR2-K-500 AC/DC24.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the frronnt of the communication E5AK-TPRR2-K-500 AC/DC24.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.