Cable specifications: Fire-retardant, Robot cable.
Cable length L: 2 m.
Cable outer diameter: 6 mm.
Straight Connectors.
Minimum order: 5.
UL: Yes.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors .
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock E52-CA20A-1 D=8 2M.
A positive click indicates locking
E52-CA20A-1 D=8 2M
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Size: 48 x 24mm.
Control output 1: voltage output (SSR driver).
Control output 2:-- E52-CA20A-1 D=8 2M.
Auxiliary output: -.
Power supply voltage: AC100 ~ 240V .
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc E52-CA20A-1 D=8 2M. .
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately). Name: Repeater Unit.
Specifications: A sub-trunk line can be,
connected downstream,
(for trunk-branch line configuration),
or further branching is enabled downstream,
(for configurations with no wiring restrictions),
in the same way as for a Master Unit.
A Repeater Unit can be used to branch,
the trunk line and increase the,
number of connected Units,
as well as to extend the length of the,
communications line.
Standards: CE, U, U1, L, N.
Simple and Intelligent Bit Slaves,
with Industry-standard e-CON connectors.
Slave Units capable of 2-point bit-level distribution.
The I/O power suupply is supplied from the communications,
power in the previously connected flat cable, and has a,
short-circuit detection function for protection E52-CA20A-1 D=8 2M.
Industry-standard e-CON connectors.
Short-circuit protection safeguards the network,
from I/O shhort circuits E52-CA20A-1 D=8 2M.
Simple communications connections,
with flat cable and connectors.
Bit-level distribution to support,
essentially any application.
E52-CA20A-1 D=8 2M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E52-CA20A-1 D=8 2M&select=5