Main contacts: 3PST-NO.
Auxiliary contact: SPST-NC.
Number of input channels: None (direct breaking).
Reset mode: Auto-reset.
Input type: --.
Rated voltage: 24 VDC.
Ultra Slim Safety Relay Unit.
Models of width 17.5 mm available with 2 or 3 poles. Models.
of width 22.5 mm with 3 poles also available .
Conforms to EN standards. (TÜV approval) E3X-DAB6.
DIN track mounting possible. Temperature range: -50°C to 50°C
E3X-DAB6
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E3X-DAB6. Name: HFU (gradient temperature control) (See note 1.).
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sourcing) E3X-DAB6.
Functions: Heater burnout alarm, None; Event inputs, 4.
Communications functions: From End Unit, Port A, RS-485; Port C, RS-485;
or RS-232C, selectable.
Input type: No input.
Terminal: M3 terminal .
Gradient Temperature Control to Achieve.
Consistent Layer Temperature.
Perform gradient temperature control ranging from 2 to 32 channels.
Perform 2-channel gradient temperature control for up to 16,
groups, or 32-channel gradient temperature control for up to 2 groups.
Set gradient temperature control or 2-PID control for each group.
Reduce design work for ladder programming with programless,
connections to Programmable Controllers. (The same feature,
as Standard-control EJ1 Models.).
Connect directly to the G3ZA Multi-channel Power Controller,
using optimum cycle control for high-accuracy control with minimal noise. Contact form: 4PDT.
Classification: Standard model.
Plug-in termminals E3X-DAB6.
Fully Sealed Versioon of G2A that Displays Its .
Power in Adverse Environments.
Exhibits stable performance in an adverse atmosphere of,
harmful gas, moisture, or powdery dust due to its hermetically,
sealed construction.
All the mechanical components of the Relaay have been,
annealed to prevent gas generation inside the Relay E3X-DAB6.
Economical as compared with a hermetically sealed relay in a,
metallic enclosure.
E3X-DAB6 Operation manual/Instructions/Model selection sample download link: