Output: DPDT.
Lighting: LED without Voltage Reduction Unit.
Operating voltage: 24 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28 . 5 mm, the smallest class in the industry E3X-DA6SE-S.
Detachable Switch.
The same contacts can be used for both standard loads and microloads
E3X-DA6SE-S
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Classification: General purpose Models.
Description: Sheathed platinum resistance thermometer.
Temperature range (See note 3.): -200°C to 450°C E3X-DA6SE-S.
Element type: Pt100.
Conductor type: 3-conductor system .
Class: B.
Protective tubing material: ASTM316L.
Terminal type: Exposed terminals.
Page: 6.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers E3X-DA6SE-S.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal . Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 1500W.
Output voltage: 24V.
Output current: 65A (AC100V) 70A (AC200V) peak current 105A (AC200V).
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W outputt terminals)
Support finger touch protection to prevent electric shock E3X-DA6SE-S.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whenn tthe fan is replaced by the customer E3X-DA6SE-S. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"
E3X-DA6SE-S Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E3X-DA6SE-S&select=5