Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Plastic rod.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models . )
Sealing characteristics that meet IEC IP67 degree of protection E3S-LS3N 0.5M.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material
E3S-LS3N 0.5M
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables E3S-LS3N 0.5M.
Multiple mounting possible with Switches with Plungers .
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Model: CPM2C-20C1DR-D. CPU Unit: Units with 20 I/O points.
I/O terminal block.
Inputs: 12 inputs.
Outputs: 8 outputs E3S-LS3N 0.5M.
Input type: 24 VDC.
Output type: relay .
Internal clock: Yes.Size: 48 x 48mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 3 points (common universal).
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater disconnection, SSR fault detection function: 1 points.
Communication: -.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remotee SP input function, suupport for a variety of applications E3S-LS3N 0.5M.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermmo (sold separately) E3S-LS3N 0.5M.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
E3S-LS3N 0.5M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E3S-LS3N 0.5M&select=5