Control output 1: Relay output.
Control output 2: Relay output.
Auxiliary output: Two.
Communications: RS-485.
Heater burnout: One.
Event inputs: Two.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance E3S-AD63 2M.
Handles More Applications.
The white PV display with a height of 15
E3S-AD63 2M2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other E3S-AD63 2M. Size: 48 * 48mm, terminal type .
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: RS-232C.
New program type E3S-AD63 2M.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved .
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Actuator: Roller lever R38.
Item: Airtight seal, High-sensitivity.
Pretravel (PT): 10°.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including Geneeral-purpose,
Environmennt-resistant, and Spatter prevention Switches E3S-AD63 2M.
Standard-feature gold-clad crossbar contacts provide high reliability.
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, aandd four-direction head mounting E3S-AD63 2M.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models.
E3S-AD63 2M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E3S-AD63 2M&select=5