Lock method: Mechanical lock.
Conduit size: M20.
Voltage for solenoid: 24 VDC.
With LED indicator 2NC+ 1NC (Slow-action).
Release Protective Cover Locks Using.
Controller Signals or Pushbutton.
Switches after the Cutting Tool Stops.
Moving Due to Inertia.
A mechanical lock is applied automatically when the Operation .
Key is inserted E39-ZHC1 4.8M. A high level of safety is achieved using a,
mechanism where the lock is only released when voltage is,
applied to the solenoid
E39-ZHC1 4.8M
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL, CSA and CCC standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened E39-ZHC1 4.8M.
Direct opening mechanism that is EN-certified is indicated by,
on the Switch .
Auxiliary release key ensures easy maintenance and unlocks the,
door in the case of a power failure.
Tough aluminum die-cast body incorporating a switch box with,
degree of protection satisfying IP67, UL, and CSA TYPE6P, 13.
Equipped with a horizontal and vertical conduit opening E39-ZHC1 4.8M.
Models incorporating easy-to-see indicators for monitoring and,
those using an adjustable Operation Key for a swinging door are available .
The mounting direction of the head can be changed,
to allow the Operation Key to be inserted from four directions. No. of cable cores: 4.
Cable connection direction: Straight.
Cable length L: 0.3 m.
Small Round Water-resistive.
Connectors.
Water-resistive, compact connector meets IP67 requirements.
Conventional M8 screw-mounting models are available along with,
S8 snap-in models that connect and disconnect with one touch.
Ideal for a wide variety of FA and OA applications.
Connectors on both cable ends require no harness work.
Some new M8 models with 3 or 5 poles. Input capacity: 16 points.
Mounted relays: NY-5W-K-IE (Fujitsu Component).
Rated load: Resistance load,
250 VAC 2 A/output, common 8 A,
30 VDC 2 A/output, common 8 A.
Rated ON current: 3 A/output.
Maximum contact voltage: 250 VAC, 125 VDC.
Maximum contact current: 3 A/output.
Maximum switching capacity: 750 VAAC, 90 WDC.
Minimum applicable load(reference value): 5 VDC 1mA.
Mechanical service life: 20,000,000 operations min.
Electrical service life: 100,000 operations min.
Number of circuits per common: 8 points/common.
Output indicators: LED display (yellow).
Isolation method: Relay isolation.
I/O power supply method: The relay drive power,
is supplied from the unit power supply.
Unit power supply current consumption:
210 mA max. (for 20.4 to 26.4-VDC power supply voltage).
Weight: 290 g max.
Expansion functions: Enabled.
Output handling for communica tions errors:
Select either hold or clear.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unitt can be connected E39-ZHC1 4.8M.
(OOne expansion unit per one I/O terminal unit .)
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary sswiitch and with tool software E39-ZHC1 4.8M.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance.
E39-ZHC1 4.8M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E39-ZHC1 4.8M&select=5