Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- E2FM-X5B1 2M.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance
E2FM-X5B1 2M Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0 E2FM-X5B1 2M. 2% FS (previous models: ±0 . 5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter E2FM-X5B1 2M.
Switch the PV display between three colors .
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. E32-T81F-S type: resistant to environmental type; resistant to drugs,
Specialty: Teflon coating heat: 200 degrees,
Shape / detection distance (mm): 920; 700; 460 (190),
Bending radius (mm): R10.
Standard test object (minimum test object) (mm) 1: 1 (0.005),
Fiber element for meeting diversified needsE32-D12R type: standard type; soft (new standard),
Specialty: diameter 3 cylinder,
Bending radius (mm): R; R1.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsDaily Time Control with Simple Operations,
Specify the operation days.
(However, you can set only one pattern of operation days,
and specified days.)
Up to 12 ON/OFF operations (24 for pulse-output operation).
Special holidays can be handled easily with the holiday,
setting function.
Adjustmments for sudden schedulle changes can be made eas,
ily using output override and automatic return operation E2FM-X5B1 2M.
The operation program can be checked easily with the program check function.
Enables pulse output operation and summer time setting.
Incorporates finger-safe teerminals E2FM-X5B1 2M.
Conforms to UL, CSA, and CE marking.
Meets a variety of mounting requirements: flush mounting,
surface mounting, and DIN track mounting.
E2FM-X5B1 2M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2FM-X5B1 2M&select=5