Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 35 W.
Output voltage: 5 V.
Output current: 7 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V) E2E-X5Y2 2M.
Easy Mounting: Front-mounted type, DIN rail-mounted type are available
E2E-X5Y2 2M
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3 E2E-X5Y2 2M.
(EMI:EN55011 ClassA) .
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling E2E-X5Y2 2M.
Auxiliary output points: 2 points .
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 4.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Throughh the support software (VVer E2E-X5Y2 2M.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the frronnt of the communication E2E-X5Y2 2M.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
E2E-X5Y2 2M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2E-X5Y2 2M&select=5