Model: DSR (67S).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular .
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system
E2E-X2MF1-R 2M
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system E2E-X2MF1-R 2M.
Can also correspond to the generator and the electric side / internal tributaries .
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident E2E-X2MF1-R 2M.
2 stage cross terminal stand with cover with convenient wiring . Setting: simulation settings.
Indication mode: no indication.
Adjustment mode: ON/OFF action.
Output: relay.
Input: component interchange type thermistor.
The size of the DIN48 to achieve the simulation set, low cost.
The most small and realize the low cost of.
Proportional (P) action in the regulation mode.
And the reset function is added.
Through the installation of the adapter can be continuously close.
The installation of DIN guide rail and panel mounting can be carried out by means of insertion. Type of input: AC voltage input.
Output type: relay contact; 1c HH; PASS, H, L, LL: each 1a.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models arre not equipped with ddepth E2E-X2MF1-R 2M.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge forr mmonitoring the operation trend E2E-X2MF1-R 2M.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet type system
E2E-X2MF1-R 2M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2E-X2MF1-R 2M&select=5