LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
E2E-X20MD1-M1GJ 0.3M
OMRON E2E-X20MD1-M1GJ 0.3M
Actuator: Adjustable rod lever 25 to 140 mm.
Item: Heat-resistant; Basic.
Pretravel (PT): 25±5°.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches .
Standard-feature gold-clad crossbar contacts provide high reliability E2E-X20MD1-M1GJ 0.3M
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models E2E-X20MD1-M1GJ 0.3M. No. of notches: 3 notches .
Output: DPDT.
Reset method: Manual.
Lighting method: Non-lighted.
Separate Construction with Cylindrical.
16-dia. Body.
Same separate construction as the A16-series Pushbuttons with,
Miniature Design of 28.5 mm.
The same contacts can be used for both standard loads and,
microloads.
Oil-resistant IP65 models,
Conforms to EN60947-5-1 E2E-X20MD1-M1GJ 0.3M. Type: S8JC-ZS series models list .
Meet the criteria: CE (EN50178).
Configuration: power supply with cover; bottom surface mounting.
Input voltage: 200 ~ 240VAC.
Rated power: 15W.
Output voltage: 5VDC.
Output current: 3.0A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-232C.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the statte of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E2E-X20MD1-M1GJ 0.3M.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation E2E-X20MD1-M1GJ 0.3M.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
E2E-X20MD1-M1GJ 0.3M Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=E2E-X20MD1-M1GJ 0.3M&select=5