Power supply voltage: 24V DC±10%, Ripple (p-p): 10%.
Current consumption: 1.2A max.
Discharge voltage: ±7.5kV.
Discharge method: Variable DC.
Ionization time: 1 s.
Ion balance: ±10V max.
Amount of ozone generated: 0.01 ppm,
(Measured at a distance of 50 mm from air outlet).
Indicators: Power (Green), Fan running (Green), Cleaning (Yellow), Alarm (Red) E2E-X10ME25-Z 2M.
Main functions: Ion balance adjustment (Automatic and manual)
E2E-X10ME25-Z 2M
External output (for both cleaning and alarm outputs): Photo MOS relay output,
(NPN or PNP)Applied voltage: 30VDC max., load current: 100mA max.
Residual voltage: 1V max.
Discharge stop input: No-voltage contact input, ON: 0V short circuit,
OFF: Open (leakage current: 0 E2E-X10ME25-Z 2M. 1mA max.).
Ambient temperature range: 0 to 50˚C (No icing or dewing).
Ambient humidity range: 35% to 65% (No icing or dewing).
Weight (Packaged): Approx. 1 kg (Approx. 1.8 kg).
Material: Body:Aluminum, ABS Electrode needle: Tungsten.
Accessories: Instruction sheet, I/O connector, Stand, Streamer.
This ionizer series is designed to go anywhere E2E-X10ME25-Z 2M.
All models are easily installed on narrow,
workbenches or in high positions where earlier,
models presented installation issues . Classification: Equipped with operation indicator and diode to absorb coil surge.
Contact form: 4PST (standard).
Mounting method: Screw mounting .
Terminals: Flat-bladed screw terminal.
Rated voltage: 5 VDC, 12 VDC, 24 VDC.
Compact Terminal Relay with 4 Independent.
Outputs.
Equipped with four G6B Mini-relays that are compact, highly sen,
sitive, and highly resistant to dielectric surges, and that can switch,
5 ampss of power E2E-X10ME25-Z 2M.
Sealed plastic construction used for relays .
Easy wiring with separated input/output terminals.
Special P6B Mounting Socket used to facilitate maintenance,
(except for high-reliability models).
UL and CSA certification for standard models,
(except foor high-reliability models) E2E-X10ME25-Z 2M.
VDE certification for G6B-4BND/47BND/48BND for 12/24 VDC.
DIN Track mounting, and screw mounting models are available.
E2E-X10ME25-Z 2M Operation manual/Instructions/Model selection sample download link: