Isolation: Phototriac coupler.
Zero cross function: No.
Indicator: Yes.
Rated output load: 3 A at 100 to 240 VAC (See note 1.).
Rated input voltage: 24 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”) DRT2-OD04CL.
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input
DRT2-OD04CL
(model numbers with “N” before the suffix). Actuator: One-way roller arm lever (horizontal).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards DRT2-OD04CL.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) DRT2-OD04CL.
Certified standards: UL, EN (TÜV), and CCC. Shape: Heat-resistant, cylindrical.
Dimensions: M12 x 22 mm.
Sensing distance: 2 mm.
Resolution: 1 μm.
High-accuracy Detection of Metal Workpiece Displacement.
Sensor Heads support a wide variety of applications.
Linearity can be adjusted for non-ferrous metals,
such as SUS and aluminum, using the material selection function.
Simple linearity compensation (teaching).
Easily perform calculation for two Sensors by using a Calculating Unit.
Prevent mutual interference for up to five Units by using a Calculating Unit. Actuator: Cat whisker.
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC (Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NNC/1NO, 2NC, 2NC/1NO and,,
3NC contact forms DRT2-OD04CL.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used witth both standard loads and microloads DRT2-OD04CL.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.
DRT2-OD04CL Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=DRT2-OD04CL&select=5