Head material: Plastic*1.
Release key position: Bottom.
Release key type: Standard (resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 2NC/1NO+2NC D4SL-N2GFG-D.
Conduit opening: Pg13
D4SL-N2GFG-D5.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility.
Built-in switches with multiple-contact construction are available D4SL-N2GFG-D.
Key holding force of 1,300 N minimum .
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available. Protective tubing length: 100mm.
Lead wire length: 1m.
Element type: J (IC).
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work D4SL-N2GFG-D.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Type of drive rod: roller plunger type.
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (1NC).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC).
Forced open action structure.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used. Illumination: Non-lighted.
Pushbutton color: Gray.
Pushbutton size: 30 dia.
Terminal: Solder terminal.
Contact form: TPST-NC.
Separate Construction withh Smallest D4SL-N2GFG-D.
Class of Deepth in the World .
Direct opening mechanism to open contacts in emergencies,
such as when they are welded.
Conforms to EN 60947-5-5.
Includes a safety lock to prevent misuse.
Features separate construction that allows the Switch to be,
separaateed for easier wiring and one-piece construction that,
allows easier handling D4SL-N2GFG-D.
Models available with 3 contacts built into a single block (A165E-U).
D4SL-N2GFG-D Operation manual/Instructions/Model selection sample download link: