Actuator: Roller lever (stainless steel roller).
Conduit openings: M20.
1NC/1NO (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts D40Z-1C2-S.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever
D40Z-1C2-S
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties D40Z-1C2-S.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13).
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Classification: Momentary operation.
Shape of Operation Unit: 13 dia.
Output: 2 *2.
Operation Unit color: Blue (-A).
Built-in V-series Miniature Basic.
Switch for Compatibility with D40Z-1C2-S.
Business and Consumer Equipment .
Momentary operation and lock.
Operation Unit available in six colors.
Improved sense of touch with built-in miniature basic switch. Contact form: SPST-NO/SPST-NC.
Type: Models with Built-in Operation Indicators.
Rated voltage: AC: 24, 100, 110, 120, 200, 220, 230, 240;
DC: 12, 24, 48, 110, 220.
MK-S-series Relays with DC-switching,
Models That Can Switch 220 VDC, 10 A,
(Resistive Load).
Switch a DC load of 220 VDC, 10 A (resistive load).
Models for AC Loads can switch 250 VAC, 15 A (resistive load).
Lineup includes models with SPST-NO and SPST-NO/SPST,
NC contact forms.
Using a SPST-NO/SPST-NC contact form enables detecting,
contact welding. (When the NO contacts become welded, the,
NC contacts will maintain a minimum distance of 0.5 mm.).
Models available with operation indicators and built-in test buttons.
RoHS compliant.
Standards: UL, IEC (TÜV certification). Ontology: program type.
Size: 48 x 96mm.
Type: 2 input type.
Control mode: 2 channel standard control /1 channel heating and cooling control /1 channel sseries control and other ffunctions D40Z-1C2-S.
Output (control / transfer) points: 2 points (pulse + pulse / current).
Output (SUB) points: 2 points.
Event entry point: 4.
Serial communication: RS-485.
New high speed, high precision digital regulator (Cheng Xuxing)!
Can be set up to 322 kinds of procedures D40Z-1C2-S.
1 units can be coordinated to run up to 4 channels.
High speed acquisition of 50ms.
With CX-Thermo on the computer easily set.
D40Z-1C2-S Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D40Z-1C2-S&select=5