Category: incidental cover with under voltage detection function.
Structure: DIN guide rail mounting type.
Capacity: 100W.
Output voltage: 24V.
Output current: 4.5A.
Alarm output: leakage type.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device .
Built in support for determining the abnormal causes of the new under voltage detection function
D3V-161M-3C25
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free D3V-161M-3C25.
Humanized design of anti - shedding screw for terminal stage .
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer D3V-161M-3C25. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2 . (except for type 15/30W)"Type: Welding / wire type, with right column.
Drive rod: rod type Shibai leaf.
Terminal specifications: with wire, the right side of the lead.
Contact specifications: 1a.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through tthe support software (VVer D3V-161M-3C25.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the frronnt of the communication D3V-161M-3C25.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
D3V-161M-3C25 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D3V-161M-3C25&select=5