Function name: 3 phase 400V.
Power: 2.2KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 1.9KG.
Dimension (w * h) 128mm *:108.
Outline dimension (deep):170.5mm.
Mechanical automation concept .
Positioning function.
The use of options D2SW-3L3-3M.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication
D2SW-3L3-3M
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Output: DPDT D2SW-3L3-3M.
Lighting: Incandescent lamp.
Operating voltage: 5 VAC/VDC .
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads D2SW-3L3-3M.
Easy-to-wire terminal arrangement .
Certified for EN 60947-5-1. Minimum order: 50.
Material: Rubber/black.
Suitable connector: Model, XS2C/XS2R/XS2F/XS2P/XW3A/XW3B;
Mounting portion, Pin block (female pins).
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to seee the state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV D2SW-3L3-3M.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation D2SW-3L3-3M.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
D2SW-3L3-3M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=D2SW-3L3-3M&select=5