Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: output (using control output) .
Communication: - G3CN-202PL DC5.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved
G3CN-202PL DC5
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm) G3CN-202PL DC5.
High speed sampling period 60ms .
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay) G3CN-202PL DC5.
Setting the program settings that can perform flexible contact output .
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Classification: High-sensitivity.
Contact gap: H (0.25 mm).
Actuator: Panel mount cross roller plunger.
Best-selling Basic Switch Boasting.
High Precision and Wide Variety.
A large switching capacity of 15 A with high repeat accuracy.
A wide range of variations in contact form for your selection: basic,
split-contact, maintained-contact, and adjustable contact gap types.
A series of standard models for micro loads is available.
A series of molded terminal-type models incorporating safety,
terminal protective cover is available. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, connvenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV G3CN-202PL DC5.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact ouutput G3CN-202PL DC5.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
G3CN-202PL DC5 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=G3CN-202PL DC5&select=5