Cable with connector (1 to 1) /G79-I_C, G79-O_C.
L size: 250mm.
Input use
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Output: DPDT.
Lighting: LED.
Operating voltage: 12 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2 G2R-1A DC6.
Item: Alternate operation (Self-holding)
G2R-1A DC6
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement G2R-1A DC6.
Certified for EN 60947-5-1 . Size: 48 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function G2R-1A DC6.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Name: External Connector.
Model: C500-CE403.
Specifications: Pressure welded terminal; 40p.Socket body.
Representative examples of applicable models.
Timer: H3Y series; H3YN series; H3Y (N) -2-B.
Pole number: 2.
Socket for MY relay, G2R-S relay.
Save hours of Push-InPlus terminal type to add product series.
Using Plus Push-In terminal, compared with the previous screw terminals,
Save wiring time (compared with the previous screw terminals, can shorten the wiiring time of about 60%*) G2R-1A DC6. .
Screw will not loose, to achieve maintenance free.
The insertion force is small, the drawing strength is big, and the wiring time is saved, and the high reliability is simultaneously considered.
When connecting multiple strands, the use of non - hoolding mechanism,
Insert a word screwdriver to keep it G2R-1A DC6.
2 wires can be inserted in each terminal.
DIN guide rail installation, screw mounting common.
G2R-1A DC6 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=G2R-1A DC6&select=5