Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 15W.
Output voltage: 24V.
Output current: 0.65A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device .
Built in support for determining the abnormal causes of the new under voltage detection function
F3ZP-CD100-E
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free F3ZP-CD100-E.
Humanized design of anti - shedding screw for terminal stage .
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards F3ZP-CD100-E. (200V input)
High harmonic current limit: EN61000-3-2 . (except for type 15/30W)
"
Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV F3ZP-CD100-E.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation F3ZP-CD100-E.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
F3ZP-CD100-E Operation manual/Instructions/Model selection sample download link: