Actuator: Roller lever: R38.
Item: High-precision.
Connector shape: Threaded (M12).
Built-in switch type: Airtight.
Voltage: DC.
Wiring locations: NC + NO 4 core.
Connector pin No: NC 1 2; NO 3 4.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches
F3ZN-S1170N15
Standard-feature gold-clad crossbar contacts provide high reliability.
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting F3ZN-S1170N15.
Approved standards: EN/IEC, UL, cUL, and CCC .
Contact your OMRON representative for information on approved models. Sensor type and connection: 3 line DC (NPN) /2 line 3-4.
Actuator connection: actuator connection 1-4.
Port number: 4.
Cable length: 5m.
This series contains the optimal control case of the new thin,
Light connector terminal box, has better,
Environmental resistance and centralized management of I/O sensor connector,
Therefore, less artificial F3ZN-S1170N15.
Wear resistant thin, protection grade can reach IP67.
Suitable for photoelectric sensor,
Proximity sensor and sensor with I/O connector (M12) limit switch.
In addition, due to the increase of the rated current, the ground terminal is increased,
So it can support and connect the valve solenoid.
Contains power and action indicator light.
No matter how many ports are used, the installation method is used,
To ensure that the system can be easily expanded. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternaate,
between displayinng the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV F3ZN-S1170N15.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs F3ZN-S1170N15.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
F3ZN-S1170N15 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=F3ZN-S1170N15&select=5