Photomicrosensor with light,
modulation is not influenced by,
external light.
Voltage-output models with wide operating voltage,
range (5 to 24 VDC).
Fitted with an easy-to-adjust optical axis mark.
Easy adjustment and optical axis monitoring with,
a light indicator. Size: 48 x 96mm.
Ontology: terminal type, analog input type .
Category: control output 2 point type (power supply AC100 ~ 240V)
F3WN-X1537N40
Shell color: black.
Control output 1: relay output.
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use F3WN-X1537N40.
Event entry point: 2.
Transfer output: - .
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV F3WN-X1537N40.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Cable: PVC.
Cable core number (core): 3.
Cable outlet direction: L type.
Cable length L:10m.
LED:PNP.
The province, province hours maintenance, use waterproof connector environment and strong tolerance of FA.
Conform to IP67. FA small special connector flame retardant 94V-0.
The connector wiring system, convenient equipment maintenance, reduce equipment downtime.
IEC61076-2-101 (IEC60947-5-2).
For LED products, can clearly confirm the status of the sensor action.
Item: Operation indicator (LED) *1; Basic 15±5°.
Actuator: Roller lever, pre-wired connector *3; 2 conductors; DC.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including Generaal-purpose,
Environmennt-resistant, and Spatter prevention Switches F3WN-X1537N40.
Standard-feature gold-clad crossbar contacts provide high reliability.
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, aandd four-direction head mounting F3WN-X1537N40.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models.
F3WN-X1537N40 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=F3WN-X1537N40&select=5