Sensor type and connection: 3 line DC (PNP) /2 line 1-4 DC.
Actuator connection: actuator connection 3-4.
Port number: 4.
Cable length: 5m.
This series contains the optimal control case of the new thin,
Light connector terminal box, has better,
Environmental resistance and centralized management of I/O sensor connector,
Therefore, less artificial F3SN-B0187P40-02.
Wear resistant thin, protection grade can reach IP67
F3SN-B0187P40-02
Suitable for photoelectric sensor,
Proximity sensor and sensor with I/O connector (M12) limit switch.
In addition, due to the increase of the rated current, the ground terminal is increased,
So it can support and connect the valve solenoid.
Contains power and action indicator light F3SN-B0187P40-02.
No matter how many ports are used, the installation method is used,
To ensure that the system can be easily expanded . Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.470 A; 60 Hz, 0.390 A .
Rated input: 50 Hz, 50 W; 60 Hz, 48 W.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3100 r/min F3SN-B0187P40-02.
Maximum flow rate: 50 Hz, 4 . 8 m3/min; 60 Hz, 5.7 m3/min.
Maximum static pressure: 50 Hz, 104 Pa; 60 Hz, 107 Pa.
Noise: 50 Hz, 56 dB; 60 Hz, 58 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Name: Expansion Units.
Specifications: inputs ;
16 inputs; PNP;
One Expansion Unit can be,
mounted to one CRT1-ID16(-1),
CRT1-OD16(-1), CRT1-ROS16,
or CRT1-ROF16 Digital I/O Slave.
Standards: CE, UC, UC1, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made wwith CompoNet F3SN-B0187P40-02.
Wiriing material cost can be reduced .
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee . F3SN-B0187P40-02.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.
F3SN-B0187P40-02 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=F3SN-B0187P40-02&select=5