Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 3.75 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: Yes.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication .
Monitor and Simple Functions for F3SJ-A0470P20-TS.
Easy System Commissioning.
New 90-W models with indication monitor that
F3SJ-A0470P20-TS
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) F3SJ-A0470P20-TS.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Pressure range: Negative pressure; 0 to -101 kPa.
ON/OFF output: Open collector (two independent outputs).
Linear output: 1 to 5 V.
Model: NPN output.
Pressure Sensor with.
Easy-to-Read LED Display.
Pressure status can be checked at a glance from the,
digital display and bar display F3SJ-A0470P20-TS.
Measurement pressure prevents incorrect outputs due,
to momentary pressure changes.
Perform automatic teaching simply by teaching pressure,
values for good and bad products.
Industry’s smallest models at just 28 × 28 × 29 mm.
Only in hysteresis mode. Category: built-in diode (DC).
Contact form: 4DPDT.
Structure: insert / solder terminal.
Indicator: with LED indicator light.
Note: when the order is ordered, the number of the models is added with the rated voltage of the coil.
For example: AC6V AC6V, MY2-J on behalf of the rated voltage of the coil.
Upgraded version of the small power relay, there are a variety of models, suitable for a variety of sequential control and power applications. 30 years of best-selling products new upgrade in reservations,
Based on the basic functions to achieve a compact.
The installation dimensions of the surface type remain unchanged, the volume ratio of the volume ratio of the square body is reduced,
Half. (excluding AGD-U2)
Built in digital filter to reduce the impact of high frequency innterference, to achiieve a higher accuracy,
Leakage monitoring F3SJ-A0470P20-TS.
The output point consists of 1c1a * monitoring circuit, an external signal based on contact,
Remote monitoring and alarm output of each monitoring circuit.
Cube embedded type also built-in buzzer. (exceptt AAGD-U2) alarm output,
Optional external buzzer F3SJ-A0470P20-TS.
After the upgrade of all products can choose automatic reset, manual reset.
(AGD-N5, AGD-NY5, AGD-N52)