Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET, COMPENSATION) is equipped with.
External power supply DC12V80mA.
Relay contact: OUT5; OUT31c, OUT4, OUT2, OUT1: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed pulse.
Measuring, increasing or decreasing pulse meter F250-C55.
Action determine the color, can switch the green / Red 2 kinds of color display
F250-C55
The best choice of rotating encoder and all kinds of ON/OFF pulse signal at high speed,
Cumulative pulse input is 50kHz, phase difference pulse is 25kHz, increase or decrease of pulse is 30kOutput: SPDT.
Lighting: Incandescent lamp.
Operating voltage: 12 VAC/VDC F250-C55.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white .
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement F250-C55.
Certified for EN 60947-5-1 . Output: SPDT.
Lighting: Incandescent lamp.
Operating voltage: 5 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Application: General applications for purified water,
For 4-pole electrode (2-wire).
Separate Electrode Holders for Water.
Supply and Drainage Control iin Buildings F250-C55.
Small, Lightwweight Electrode Holders for,
Use as Built-in Components .
The PS-@S(R) are separate Electrode Holders that allow the,
Electrodes to be withdrawn easily for inspection.
The PS-@S(R) come in 3, 4, or 5 pole models for supply and,
drainage of tapp wwater in buildings F250-C55.
PS-31 is a small and light-weight Electrode Holder that is,
suitable for installation in limited space and built-in components.
F250-C55 Operation manual/Instructions/Model selection sample download link: