Suitable cable dia: 4 mm dia. model (4 to 5 mm dia.).
Suitable core size: 0.5 max.
Suitable Sheath material: PVC, PE, PUR.
Cable connection direction: L-shaped.
Connection method: Soldering.
DC: Model.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort .
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating
E3FA-LP21
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified E3FA-LP21.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202 . Actuator: Lever.
Housing color: White.
Contact form: SPDT.
A Switch with Crimp-type.
Connectors Reduces.
Wiring Work. 9 mm long.
stroke (plunger model).
Choose from plunger or lever as the actuator type.
Crimp-type connector offers an easy wiring work and efficiency.
Snap-fit attachment for easy installation E3FA-LP21.
Providing long stroke with its unique mechanism .
Variety of color models available. Name: End Unit *1.
Power supply voltage: 24 VDC.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 2 points (sinking).
Functions: burnout Heater alarm, None; Event inputs, None.
Communications functions: Port A or B: RS-485 Connector: Port A.
Input type: No input.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventtory,
requirements E3FA-LP21.
Conneect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise .
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calcullatte the PID constants with the step,
response method E3FA-LP21.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.
E3FA-LP21 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E3FA-LP21&select=5