Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Right-angle/RJ45).
Cable length: 2 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V) .
Shell color: black.
Control output: current output E2V-X4B2-M1.
Control mode: standard or heating cooling
E2V-X4B2-M1
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / E2V-X4B2-M1.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay E2V-X4B2-M1.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Operation indicator: Without operating indication; Microload.
Ratings: 0.1 A at 125 VAC; 0.1 A at 30 VDC.
Actuator: Adjustable roller lever.
Cable length : 5m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrancee sealed via encapsulatinng material E2V-X4B2-M1.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
conffirrmation of operation E2V-X4B2-M1.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
E2V-X4B2-M1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2V-X4B2-M1&select=5