8 pts, No-voltage contact. PNP.C1000H-CP CPU 62 k words 1024 pts C1000H-CPU01-E.Cable Specifications: Heat-resistant cable up to 105°C *.
Cable connection direction: L-shaped.
Cable diameter: 6.0 mm dia.
No. of cable cores: 4.
Cable core cross sectional area: 0.5 mm.
Cable length: 5 m.
DC.
Minimum order: 5 .
UL-listed: --.
Water- and Environment-resistive FA E2G-M30KN18-M1-B1.
Connectors Save Wiring and Maintenance Effort
E2G-M30KN18-M1-B1
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available E2G-M30KN18-M1-B1.
Three types of Connector Assembly: Crimping, soldering, and screw-on .
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Model: CPM2C-10CDTM-D. CPU Unit: Units with 10 I/O points.
2 MIL connectors.
Inputs: 6 inputs.
Outputs: 4 outputs.
Input type: 24 VDC.
Output type: sinking transistor.
Internal clock: --.Appearance: ADR shell E2G-M30KN18-M1-B1.
Circuit structure and open circuit mode: single contact 1C, voltage, no voltage, DC circuit breaker .
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit elements: 0.25-0.5-1-2-3-4-5-6-7-8-9-10-15-30-60-120,
Minimum action value, adjust the scale of movement, 300% over current, 10s plus or minus 17%;
700% over current, 16.7s plus or minus 12%; instantaneous elements: 200% over current, 50ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: closed circuit, 110V 5A L/R=0ms1000 DC220V times, 10A L/R=0ms1000 DC times;
30W (DC 110V 1A closed, L/R=25ms1000), 80VA (AC 220V 1A) cos with =0.1 1000.
Contact: AC250V, 5A, cos, DC30V, 5A, =1; Cos =1.
Automatic experiment: there.
Display: measurement display, resolution. Display resolution 9.9A the following is 0.1A, more than 1A.
Display range: 2.0A-20A, output display, trip (R phase and T phase) manual reset,
Instant manual reset type.
Excitation surge current suppression (fuzzy inference): the relative basic wave component second harmonic components of the containing rate is higher than 5%,
In the above area, the excitation surge current can be suppressed.
Quality: about 1.2kg.
External: Mount Searl N1.5.
Digital over current K2CA-H type,
Using the advanced techhnology of fuzzy innference to make the protection and coordination of digital DCR E2G-M30KN18-M1-B1.
And automatic testing machine, so that the relay test is easy.
By using fuzzy inference, the excitation surge current is reduced.
Improve reliability by monitoring function at any timme E2G-M30KN18-M1-B1.
With 1 sets of three-phase protection.
To save space, save wiring to make contribution.
Based on the DIN standard size, small depth is only 88.5mm.
E2G-M30KN18-M1-B1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2G-M30KN18-M1-B1&select=5