Contact type: Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A).
Operation: Momentary operation (Self-resetting).
Case color: Black.
Output: DPDT.
Lighting: LED; 24 VDC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness E2EL-X2ME1 2M.
Three-color models (green, orange, red; chameleon lighting)
E2EL-X2ME1 2M
included in lineup. Actuator: Shaft.
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and E2EL-X2ME1 2M.
3NC contact forms in addition to the previous contact forms .
1NC/1NO, and 2NC. Models with MBB contacts are also available.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output E2EL-X2ME1 2M.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through tthe support software (VVer E2EL-X2ME1 2M.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the frronnt of the communication E2EL-X2ME1 2M.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
E2EL-X2ME1 2M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2EL-X2ME1 2M&select=5