Contact type: Standard load (250 VAC, 2 A; 125 VDC 0.4 A).
Operation: Momentary operation (Self-resetting).
Output: SPDT.
Lighting: LED, 12 VDC.
Operation Unit color symbol: Enter the desired color symbol for the,
Pushbutton in @ R (Red); Y (Yellow); G (Green); A (Blue); W (White).
Pushbutton Switch Series with .
Square 40-mm Body E2B-S08KN02-MC-B2.
Combines miniature design with distinct but soft sense of operation
E2B-S08KN02-MC-B2
Easy panel mounting from the front and simple lamp replacement.
without tools. Size: M8(Stainless steel)(See note 2.); Double; Shielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Short E2B-S08KN02-MC-B2.
Output configuration: PNP.
Operation mode NO .
A new generation in global applications. DIN 48 x 24-mm Total Counter/Time Counter,
with Easy-to-read Displays and Water and,
Oil Resistance Equivalent to IP66.
High-visibility, negative transmissive LCD display with 8.5-mmhigh characters and, built-in red LED backlight at low power.
consumption.
IP66 with oil resistance and NEMA 4 protection achieved by,
unifying the front with the case and by using oil-resistant parts,
and materials E2B-S08KN02-MC-B2.
Compact (80 mm) body.
Just change a switch setting for either an NPN or PNP input.
Supports both external resetting and manual resetting.
Finger-protection terminal block cover prevents electrical shock,
and conforms to VDE0106, Part 100.
Certified for UL and CSA safety standards.
Complies with EMC standards (EN 61326) and CE Marking. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control metthods,
including OON/OFF control, phase control, and cyclic control E2B-S08KN02-MC-B2.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreentt relay or for motor or lamp loads E2B-S08KN02-MC-B2.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
E2B-S08KN02-MC-B2 Operation manual/Instructions/Model selection sample download link: