Actuator: Shaft.
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 1NC/1NO MBB (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms .
1NC/1NO, and 2NC E2B-M12KN08-M1-C2. Models with MBB contacts are also available.
Standardized gold-clad contacts provide high contact reliability
E2B-M12KN08-M1-C2
Can be used with both standard loads and microloads. Cable specifications: Spatter-resistant Cable.
Cable length L: 1 m.
Cable outer diameter: 6.6 mm.
Straight Connectors.
Minimum order: 10 E2B-M12KN08-M1-C2.
UL: --.
Round Water-resistive Smartclick .
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned E2B-M12KN08-M1-C2.
Connectors with Cables are UL approved. Actuator: Coil spring (spring diameter: 6 . 5).
Indicator: LED.
Item: Basic.
Pretravel (PT): 20±10 mm.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches.
Standard-feature gold-clad crossbar contacts provide high reliability.
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models. Appearance: insert type.
Control supply voltage: AC200/220/240V.
Action elements: overload detection.
Action characteristic: anti time limit action type.
Especially suitable for single phase motor over current protection.
Can be used for motor overload protection, common single-phase circuit of the AC current detection.
A variety of models, such as anti ttime limit characteeristics, lock time, instantaneous action, etc E2B-M12KN08-M1-C2., are provided,
The product is rich in variety, and can be effectively protected, detected and controlled according to the actual situation.
When the current is large, the input resistance of the CT orr tthe relay part is not needed, and the use is simple E2B-M12KN08-M1-C2.
Because it is a plug-in, installation, disassembly, wiring and other operations are very simple.