Optical system: diffuse type.
Detection distance: 50 positive and negative 5mm.
Beam shape: point beam.
Beam diameter: diameter of 50 m.
Resolution: 0.8 M.
Cable length: 0.5m. Sensing method: Diffuse reflective.
Connection method: Pre-wired (2 m).
Sensing distance: 1m.
Model: NPN output .
Stainless Steel Housing Ideal for Food Industry PAT Pending E2A-M30LS15-M1-C1.
Strong resistance against detergents, disinfectants, and jet liquid flow
E2A-M30LS15-M1-C1
Product lineup includes BGS Reflective Models and Through-beam,
Models with built-in slits.
Certified by Ecolab Europe.
Supply voltage: 24 to 230 VAC (50/60Hz)/24 to 48 VDC.
Control output: Contact output: SPDT (time-limit output SPDT) E2A-M30LS15-M1-C1.
Input type: No-input available .
Operating mode(see note): Eight multi-modes: Four multi-modes: A, B2, E, J.
Model: Screw terminal type.
Eight operating modes (H3DS-M) and four operating modes,
(H3DS-S) cover a wide range of applications.
A wide time setting range of 0.10 s to 120 h.
Two LEDs indicate power and relay status respectively. Case color: Black.
Control output: Voltage output (for driving SSR) E2A-M30LS15-M1-C1.
Control mode *1: Standard or heating/cooling .
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-Q1TC;
Resistance thermometer input, E5GN-Q1P.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displayinng the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E2A-M30LS15-M1-C1.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E2A-M30LS15-M1-C1.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
E2A-M30LS15-M1-C1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2A-M30LS15-M1-C1&select=5