Rated voltage: 200 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2300 r/min; 60 Hz, 2600 r/min.
Maximum flow rate: 50 Hz, 2.4 m3/min; 60 Hz, 2.8 m3/min.
Maximum static pressure: 50 Hz, 41 Pa; 60 Hz, 45 Pa.
Noise: 50 Hz, 45 dB; 60 Hz, 48 dB .
Weight: Approx. 3410 g E2A-M12KN08-M1-B1.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting
E2A-M12KN08-M1-B1
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws) E2A-M12KN08-M1-B1.
Optional Replacement Filter and Vent Attachment .
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Square socket.
Equipped with a wide variety of square and round sockets,
Surface connection and back connection.
With a finger touch protection type.
With the fixed bracket, PYF cross tab E2A-M12KN08-M1-B1.
Add no screw series. Total length: 370 mm .
Effective length: 500 mm.
The highest level of ionization in its class.
Sensing and variable-AC system provides fast and meticulous ionization.
Linked Ionizers cover a wide area without causing uneven ionization.
Digital ion display provides simple and reliable settings. Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation E2A-M12KN08-M1-B1.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions E2A-M12KN08-M1-B1. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
E2A-M12KN08-M1-B1 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E2A-M12KN08-M1-B1&select=5