Actuator: One-way roller arm lever (horizontal).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms .
(Slow-action models with MBB contacts are available ZS-HLDS2VT 0.5M. )
M12-connector models are also available, saving on labor and,
simplifying replacement
ZS-HLDS2VT 0.5M
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC ZS-HLDS2VT 0.5M. Lock method: Front lock .
Pin shape: Solder cup pin.
Applicable wire diameter: AWG20 to 28.
DC: Model.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime ZS-HLDS2VT 0.5M.
Connectors with Cables and Connector Assemblies are available .
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.
Small, easy to use.
Detection mode: diffuse reflection type.
Shape: horizontal type.
Connection mode: lead wire.
Detection range: red light 200mm.
Output mode: PNP output. Cable with connector (1 to 2) /G79-O_C-_, G79-I_C-_.
L size: A, 3000mm; B, 2750mm.
Output use.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: transfer output (special terminal).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see thee state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV ZS-HLDS2VT 0.5M.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation ZS-HLDS2VT 0.5M.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
ZS-HLDS2VT 0.5M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=ZS-HLDS2VT 0.5M&select=5