Input points: 32 points.
Input voltage: DC12/24V.
Current: 3/7mA.
Response time: 10ms.
Positive / negative sharing.
50 point terminal station.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation .
Read only memory QD75P1N. Manufacturers use, content can not be changed, power does not disappear
QD75P1N
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference QD75P1N. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read QD75P1N.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay. Max input / output points: 16 points.
Power supply voltage: 24VDC.
Input points: 8 points.
Output points: 8 points.
Output type: relay.
Power consumption: 20W.
Weight (kg):0.6.
Size (WxHxD) mm:130x90x87.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and dataa via modem communications
Paassword protection, using a eight digit password to protect your program QD75P1N.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off tthe continuous scan time QD75P1N.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
QD75P1N Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=QD75P1N&select=5