Motor: HA-LH type.
Power: 15kw.
Speed: 2000r/min.
According to the types of power supply: can be divided into DC motor and AC motor.
The structure and working principle of DC motor can be divided into four parts: brushless DC motor and brushless DC motor.
Brushless DC motor can be divided into: permanent magnet DC motor and DC motor .
DC Motor Division: Series DC motor, DC motor, DC motor and DC motor
Q65BL
Permanent magnet DC Motor Division: rare earth permanent magnet DC motor, ferrite permanent magnet DC motor and aluminum nickel Gu Yongci DC motor. Enter 16 points or 16 points.
Directly connected to the input and output terminals of PLC;
Can play a role in replacing the terminal row;
Can also be far away from the PLC of the site when the input and output devices;
Use as relay;
In order to reduce the time of the input and output connection Q65BL. Superior high efficiency IPM motor.
Output power: 22kw.
Rated speed: 1500r/min.
Voltage level: 200V.
IPM motor MM-EFS series can not be used to run the power frequency power.
The total wiring length of the IPM motor shall not exceed 100m Q65BL.
1 inverters can not connect multiple IPM motors at the same time . Cable length: 0.7 meters.
Extending cable to connect CPU main substrate and extended substrate,
According to the model can provide different cable length,
If you need to connect the AnN type expansion substrate is required,
Selection of A1SC05NB (A1SC07NB) cable. Input points: 32 points.
Voltage: DC12/24V.
Current: 2.5/5mA.
Response time: 10ms.
8 points / a common end.
Positive / negative sharing.
38 point terminal station.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selecction,
Under the premise of meeeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC Q65BL.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation Q65BL.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
Q65BL Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=Q65BL&select=5