Input and output points: 40 points.
Power supply: DC24V.
Input points: 24 points.
Output points: 16 points.
Output form: relay output.
Power consumption: 25W.
Weight: 0.7KG.
Outline dimension: 130x90x86mm.
FX3GE on the performance of the FX3GA increased analog input / output and Ethernet communication and other built-in features .
Applicable to a wide variety of applications Q3MEM-4MBS-SET.
Basic unit: 24/40 point
Q3MEM-4MBS-SET
Third generation standard model.
High flexibility.
Suitable for small scale control of high cost PLC.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points.
A versatile PLC.
Built in CPU, power supply, input and output, analog input and output, Ethernet port, can be used immediately after the purchase Q3MEM-4MBS-SET.
High speed operation.
Basic instructions: 0.21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function. Input and output points: 480 points.
Input / output data points: 480 points.
Program capacity: 8k Q3MEM-4MBS-SET.
Basic command processing speed (LD command) s:1 . 25.
RAM memory capacity: 32K, power supply.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
Useer program storage cappacity: it is a measure of how much the user application can store the number of indicators Q3MEM-4MBS-SET.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General lloggical operation instructions each account for 1 words Q3MEM-4MBS-SET. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Q3MEM-4MBS-SET Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=Q3MEM-4MBS-SET&select=5