Q170CDCBL10M
No PHOTO
MITSUBISHI Q170CDCBL10M
Servo motor series: medium inertia, medium power.
Rated output: 2.0kw.
Rated speed: 2000r/min.
Electromagnetic brake: No.
Shaft end specification: Standard (straight axis).
Voltage: 400V level.
Characteristics: medium inertia has two types of low speed and high speed, suitable for different applications .
IP level: IP67.
Application example:
1, material handling system Q170CDCBL10M.
2, industrial robots.
3, X-Y working table Q170CDCBL10M
The protection level of the HF-SP/HF-JP series servo motor is IP67 (except the shaft part).
Motor capacity selection soft (MRZJW3-MOTSZ111E)
Friendly interface design, only in the mechanical description window input constant and operation mode can choose the best servo amplifier,
The servo motor and the regenerative braking options, but also in the selection window in the selection of linear servo motor and direct drive motor Q170CDCBL10M.
Characteristic
(1) 10 typical mechanical transmission structure can be used to choose
(2) user defined operating modes (location and speed control)
(3) in the selection process, the feed speed and torque can be displayed in a graphical format Q170CDCBL10M.
(4) the calculation process can be displayed
Can easily calculate the power of the servo motor free software!Input voltage range: DC24V .
Output voltage: DC5V.
Output current: 2.5A.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
The following describes the centralized control system I/O points of the estimate.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally oopen contact is closed,

Provide load current and voltage Q170CDCBL10M.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is discoonnnected from the load Q170CDCBL10M.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
Q170CDCBL10M Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=Q170CDCBL10M&select=5