Input and output points: 96 points.
Input points: 48 points.
Input specifications: drain / source.
Output points: 48 points.
Output form: transistor output (source).
Power consumption: 14W.
Weight: 0.35KG.
Outline dimension: 85.4x90x87mm.
Hard and compact type third generation micro programmable controller .
Connector type input and output type provincial connection MR-PWS1CBL10M-A2-H.
Greatly strengthened the industry''s highest level of high-speed processing and positioning and other built-in features
MR-PWS1CBL10M-A2-H
High cost of the province space models.
FX3UC in the province of space, the province also greatly strengthened the connection of high-speed processing and positioning and other built-in features MR-PWS1CBL10M-A2-H.
The host is built in DC24V power supply, the connector input and output form of the transistor output .
In addition, according to the product mix can also achieve network communications, analog control, data collection and other functions.
Third generation high function micro programmable controller.
Connector type can save space, province wiring.
Built in high speed processing and positioning MR-PWS1CBL10M-A2-H.
Ultra small size, control points to 256 points .
Construction of CC-Link remote I/O 384 points. 8 slots.
Power supply unit.
QnAS series unit installation.
High speed access.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open coontact is closed,
Provide load current and voltage MR-PWS1CBL10M-A2-H.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is discoonnnected from the load MR-PWS1CBL10M-A2-H.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
MR-PWS1CBL10M-A2-H Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MR-PWS1CBL10M-A2-H&select=5