Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Input and output points: 1024 points.
Input / output data points: 1024 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:0.20.
Coaxial data communication line function.
Each scanning process. Focus on the input signal sampling . Focus on the output signal to refresh MR-J3ENSCBL50M-L.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read
MR-J3ENSCBL50M-L
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh MR-J3ENSCBL50M-L.
The contents of the component image register are changed with the change of the execution of the program .
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay MR-J3ENSCBL50M-L.
User program storage capacity: it is a measure of how much the user application can store the number of indicators .
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4. Smart device site unit (support for CC-LINK Second Edition).
Applicable models: GT15, GT16, GT27, GT25. Display: 7 segment digital display + icon display.
Can monitor, change the value of software components.
Can also be simple to operate, change the value.
Equipped with a button operation can be used (operator certification function) and control through the PLC control function,
Can be used with the function expansion board.
Can be installed directly to the FX3S, FX3SA, no wiring. MITSUBISHI inverter FR-D720S series.
Voltage level: single phase 200V.
Frequency converter capacity: 1.5KW.
VVVF frequency control, vector control frequency conversion, direct torque control is a kind of AC - DC - AC frequency conversion.
The common drawback is that the input power factor is low, the harmonic current is big, and the DC circuit needs large energy storage capacity,
Renewable energy and can not be fed back to the power grid, which can not be carried out in the four quadrant operation. To this end, the matrix type of AC - AC variable frequency arises at the historic moment.
Because the matrix type alternating current frequency saves the intermediate DC link, thereby, the electrolytic capacitorr with large volume and high price can be omitted MR-J3ENSCBL50M-L.
It can achieve a power factor of L, the input current is sinusoidal and can run in four quadrant, the power density of the system is large.
Although the technology is not yet mature, but still attract a large number off scholars in-depth study MR-J3ENSCBL50M-L.
In fact, the quality is not the indirect control current, flux, but the torque is directly used as the control to achieve.
MR-J3ENSCBL50M-L Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MR-J3ENSCBL50M-L&select=5