LK Automation Limited LK Automation Limited
Brand Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Home >> Price
MR-J3ENCBL2M-A2-H
MITSUBISHI MR-J3ENCBL2M-A2-H
Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0 . 1A.
External connection: 3 line /2 line type MR-J3ENCBL2M-A2-H.
Sensor connector type (E-CON type) MR-J3ENCBL2M-A2-H
Using industry standard E-CON type.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Motor series: ultra low inertia, small capacity.
Using a serial absolute / incremental encoder MR-J3ENCBL2M-A2-H.
Rated output power: 0 . 4kw.
Rated speed: 3000rpm.
With the brake with brake.
Without GB.
Shaft end: straight shaft.
The rotor of the servo motor is a permanent magnet, and the control of the servo amplifier is controlled by the U/V/W three-phase electric electromagnetic field,
The rotor rotates under the action of the magnetic field, and the encoder feedback signal of the motor is given to the driver,
According to the feedback value and the target value, the driver is compared,
Adjust the rotor rotation angle MR-J3ENCBL2M-A2-H.
The accuracy of the servo motor is determined by the resolution of the encoder. Thermocouple input.
Number of input channels: 4ch.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode.
To achieve high stability temperature control
Standard control / heating, cooling control.
The device used for the temperature control of the temperature control of the extrusion molding machine can prevent over heating and cooling.
According to the object device can choose any one of the following control method.
Standard control (heating or cooling).
Heating, cooling control (heating and cooling).
Hybrid control (combination of standard control and heating, cooling control).
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number of the upper limit output limit of each channel can be changed automatically,
Split transistor output time. To suppress the peak current.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipmment, saving the ellectricity contract), and reduce the operation cost MR-J3ENCBL2M-A2-H.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniifoorm, to ensure that the control object no local burning or thermal expansion MR-J3ENCBL2M-A2-H.
No idle running, with energy saving effect, can reduce operating costs.
MR-J3ENCBL2M-A2-H Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=MR-J3ENCBL2M-A2-H&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
Encoder cable
MR-J3ENCBL10M-A1-L
MITSUBISHI Encoder cable MR-J3ENCBL10M-A1-L
The length of the line: 10M. IP level: I
MITSUBISHI
Encoder cable
MR-J3ENCBL10M-A1-H
MITSUBISHI Encoder cable MR-J3ENCBL10M-A1-H
The length of the line: 10M. IP level: I
MITSUBISHI
Encoder cable
MR-J3ENCBL10M-A2-L
MITSUBISHI Encoder cable MR-J3ENCBL10M-A2-L
The length of the line: 10M. IP level: I
MITSUBISHI
Encoder cable
MR-J3ENCBL5M-A2-H
MITSUBISHI Encoder cable MR-J3ENCBL5M-A2-H
The length of the line: 5M. IP level: IP