MITSUBISHI inverter FR-D720S series.
Voltage level: single phase 200V.
Frequency converter capacity: 0.2KW.
VVVF frequency control, vector control frequency conversion, direct torque control is a kind of AC - DC - AC frequency conversion.
The common drawback is that the input power factor is low, the harmonic current is big, and the DC circuit needs large energy storage capacity,
Renewable energy and can not be fed back to the power grid, which can not be carried out in the four quadrant operation
MR-J2HBUS5M To this end, the matrix type of AC - AC variable frequency arises at the historic moment.
Because the matrix type alternating current frequency saves the intermediate DC link, thereby, the electrolytic capacitor with large volume and high price can be omitted MR-J2HBUS5M.
It can achieve a power factor of L, the input current is sinusoidal and can run in four quadrant, the power density of the system is large.
Although the technology is not yet mature, but still attract a large number of scholars in-depth study.
In fact, the quality is not the indirect control current, flux, but the torque is directly used as the control to achieve MR-J2HBUS5M. 16 channels.
Input: DC-10 ~ 10V, DC-20 ~ 20mA.
Output (resolution): 0 ~ 4000, 0 ~ 8000, 0 ~ 12000.
38 point terminal station.
Analog I/P multiplexing unit.
Detailed analysis of the process and work characteristics of the controlled object,
To understand the coordination between the controlled object machine, electricity and liquid,
The control requirements of the controlled object for MITSUBISHI PLC control system are put forward,
Determine the control program, to develop a design task book.
How to determine the input / output device of MITSUBISHI plc.
According to the control requirements of the system,
All input devices and output devices required for the determination of the system,
To determine the input / output device related to the MITSUBISHI PLC,
To determine the I/O PLC points. Screw, 2 piece type terminal.
Current output module.
Number of channels: 4 channels.
Number of stations: 2 stops.
Station type: remote equipment station.
High speed data transfer of up to 10MMbps;
The development of CC-LINK is not only to meet the control of high speed remote I/O,
But also to meet the high speed of the field of information control MR-J2HBUS5M.
In order to achieve this goal, the transmission speed of CC-LINK is compared with that of the previous live netwworrk system to add 40 to 10Mbps MR-J2HBUS5M.
Such a high speed can not affect the speed of the machine control while allowing a large number of data communication.
MR-J2HBUS5M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=MR-J2HBUS5M&select=5