The length of the line: 2m.
IP level: IP67.
Bending life: standard.
Encoder cable for HF-KP/HF-MP/HF-SP/HF-JP/HC-LP/HC-UP series. Output points: 4 points.
Output voltage and current: DC12/24V.
Output response time: 2ms.
4 point /1 a public side.
Output form: transistor output, leakage type.
16 point terminal station .
MITSUBISHI PLC protection and chain procedures LY40NT5P-CM.
Protection and chain is an indispensable part of the program, must be carefully considered
LY40NT5P-CM
It can avoid the control logic confusion caused by illegal operations.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system LY40NT5P-CM.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc..
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program LY40NT5P-CM.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. Needle number: 40.
Specification: loose wire connector, 5 sets (0.3mm 2). Analog input channel number: 16CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C:-.
Temperature coefficient: positive and negative 35ppm/.
Common
Conversion speed: 10ms.
Insulation between channels: isolation transformer insulation.
Absolute maximum input: positive and negative 15V, 30mA.
External wiring connection: 40 pin connector two.
Voltage input
The analog input voltage: DC - 10 - 10V.
Digital output value: 32000 ~ 32000.
Current input
Analog input current: DC0 ~ 20mA.
Digital output value: 0 ~ 32000.
Execute event driven program through alarm output
Strengthen the implementation of the interrupt function according to the alarm output flag, easy to carry out preventive maintenance.
The measured value and the change rate of the analog input signal exceed the upper and lower limits of the set,
Regardless of the procedure of the scan time, can be executed interrupt handling, quickly respond to abnormal conditions.
Analog input module for the external analog signal into the interface of the programmable controller.
Can choose the channel between the insulation, voltage input, current input, voltage / current miixed input, thermocouple input, temperature resistance (RTD) input for a variety of purposes, such as modules LY40NT5P-CM.
Filter high frequency interference.
Analog input module has been equipped with a first order lag filter.
The analog input signal with high frequency interferencee ccomponent can be obtained by using the first order lag filter LY40NT5P-CM.
Parameters can be set through the filter time constant, no program can be easy to use.
LY40NT5P-CM Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=LY40NT5P-CM&select=5