nothingInput type: AC input.
Input points: 8 points.
Enter the response time: 20ms the following.
Rated input voltage / current: AC100V/7mA.
External connection: 2 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup .
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool
HF-SN302BJ-S100 MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 75kw.
SLD converter rated current: 380A.
Structure and function: Standard model HF-SN302BJ-S100.
Type: CA.
Substrate coating: have .
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment) HF-SN302BJ-S100.
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps. 1 channels.
50/10kpps.
Count input signal: DC5/12/24V.
External input: DC5/12/24V.
Output: Transistor (open collector).
Output: DC12/24V, 0.1A/1 point, 0.8A/1 common.
47 point terminal station.
How to determine the input / output device of MITSUBISHI plc.
According to the control requirements of the system,
All input devices and output devices required for the determination of the system,
To determine the input / ooutput device relatedd to the MITSUBISHI PLC,
To determine the I/O PLC points HF-SN302BJ-S100.
Detailed analysis of the process and work characteristics of the controlled object,
To understand the coordination between the controlled object machine, electricity and liquid,
The control reequirements of the controlled object for MITSUBISHI PLC control system are put forward,
Determine the control program, to develop a design task book HF-SN302BJ-S100.
HF-SN302BJ-S100 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=HF-SN302BJ-S100&select=5